Advanced Anion and Cation Analyser

The Anion and Cation Analyser is an advanced, dual-channel analytical instrument that employs ion chromatography to simultaneously detect and quantify both anions and cations in a wide range of samples. This two-channel system is designed to analyze environmental, industrial, and biological matrices with high efficiency and accuracy.

FEATURES

  • Integrated tabletop system with dual channels for simultaneous anion and cation analysis
  • Automatic injection system with partial loop injection
  • Automatic calibration
  • Uses ion exchange columns
  • Anion channel: With suppressed conductivity detection
  • Cation channel: With optional suppressed conductivity detection
  • Powerful data analysis software for both anion and cation results
  • Anion channel: Optimized for inorganic anions
  • Cation channel: Optimized for inorganic cations

SPECIFICATION

Conductivity Measuring Range

up to 20000 μS/cm at 1 – 20 Hz sample frequency, Auto zero function for the entire measuring range, Noise: 0.1 nS/cm
Suppression Electrolytic Auto-Suppressor
Column Oven Temperature 30 °C -90 °C
Two Pumps Isocratic Pumps (analytical, non-metal – Peek version), Pressure Range: 0-40 MPa (0-6000 PSI), Flow rate: 0.001 – 10 ml/min
Degasser Integrated vacuum degasser
Injection System Automatic dual needle design to avoid system with wash program and Programmable Injection Volume: 0.1 – 999.9 μ in increments of 0.1 μl, Sample Capacity: 120 samples (1.5ml), Two sample Loops: 20 and 50 μl, Carry Over: < 0.05%
Including
  • IC column for determination of anions
  • Anionic guard column
  • IC column for determination of cations
  • Cationic guard column
  • Clarity Chromatography Software, 21 CFR Part 11 compliant

INDUSTRIES

METHODS

EPA 300.0 Determination of Inorganic Anions by Ion Chromatography
EPA 300.1 Determination of Inorganic Anions in Drinking Water by Ion Chromatography
ASTM D4327-17 Standard Test Method for Anions in Water by Suppressed Ion Chromatography
ISO 10304-1:2007 Water quality — Determination of dissolved anions by liquid chromatography of ions. Part 1: Determination of bromide, chloride, fluoride, nitrate, nitrite, phosphate and sulfate
ISO 10304-2:1995 Water quality — Determination of dissolved anions by liquid chromatography of ions. Part 2: Determination of bromide, chloride, nitrate, nitrite, orthophosphate and sulfate in waste water
ISO 10304-4:1997 Water quality — Determination of dissolved anions by liquid chromatography of ions. Part 4: Determination of chlorate, chloride and chlorite in water with low contamination
ISO 14911 Water quality — Determination of dissolved Li+, Na+, NH4+, K+, Mn2+, Ca2+, Mg2+, Sr2+ and Ba2+ using ion chromatography — Method for water and waste water
ISO 10304 Water quality — Determination of dissolved anions by liquid chromatography of ions
ASTM D6919 Standard Test Method for Determination of Dissolved Alkali and Alkaline Earth Cations and Ammonium in Water and Wastewater by Ion Chromatography

SPARES & ACCESSORIES

Porous Solvent Filter

Injection Needle for Autosampler

Check Valve Cartridge/Ceramic

Secondary Sealing Ring Analytical

Primary Sealing Ring PE Analytical

Injection Port incl. Sealing PEEK Autosampler

PEEK Capillary 0.25*1.59 mm (1/16”) 3m

Finger Tight Fitting PEEK

Anionic Guard Column

Cationic Guard Column

Ferrule f.1/16″ Capillary Mat. PTFE TM used in IC Systems for Cond. Detector

Fitting 1/4-28 Gray with Knurled Screw Head 1/16”

RELATED PRODUCTS