Polymer Additive Analyser
Polymer Additive Analyser is a dedicated system based on high-performance liquid chromatography (HPLC) with ultraviolet/visible (UV/VIS) detection to analyze different additives such as antioxidants & and Erucamide Slip in polymer formulations. HPLC is a chromatographic technique that is used to separate, identify and quantify components of a mixture. The separation in HPLC occurs due to the differential partitioning of analytes between the mobile phase (liquid) and the stationary phase (solid particles in the column). This partitioning is influenced by factors such as the chemical nature of the analytes, the composition of the mobile phase, and the properties of the stationary phase. HPLC operation parameters play a crucial role in its applications to various areas, and it is generally operated in either the normal phase or reversed phase, depending upon the nature of the sample and analytes. Almost all petroleum and petrochemical applications are carried out in the normal phase using polar stationary and non-polar mobile phases.

FEATURES
- High-resolution simultaneous analysis of various preservatives or antioxidants
- Accurate analysis
- Sufficient selectivity within a reasonable time
- A validated and sensitive HPLC method with high repeatability
- Upgradable and durable design
- Full control by PC
- Powerful data analysis software
- Exceptional sensitivity with low detection limits
SPECIFICATION
Pump |
Analytical stainless-steel low-pressure gradient version, programmable dual piston pump head for low pulsation, camshaft constantly lubricated, Flow rate: 0.001-10.000 ml/min, Pressure range: 0-40 MPa (0-6000 psi) |
Degasser | Integrated 4-channel vacuum degasser |
Detector | UV/Vis detector, Variable 1-channel UV/Vis detector with deuterium and tungsten lamp, wavelength range: 190-800nm, wavelength accuracy: ±2nm, Linearity:<2.0AU, baseline noise: ±1×10-5, 1sec Risetime |
Injection System | Automatic sample injector system, Sample capacity: 120 samples (1.5 ml), Sample loop: 100 µl, Carry over: < 0.05% with wash program; |
Including |
|
INDUSTRIES
METHODS
ASTM D5524-94 | Standard Test Method for Determination of Phenolic Antioxidants in High Density Polyethylene Using Liquid Chromatography |
ASTM D6953-18 | Standard Test Method for Determination of Antioxidants and Erucamide Slip Additives in Polyethylene Using Liquid Chromatography (LC) |
SPARES & ACCESSORIES

Porous Solvent Filter

Injection Needle for Autosampler

Check Valve Cartridge/Ceramic

Secondary Sealing Ring Analytical

Primary Sealing Ring PE Analytical

Injection Port incl. Sealing PEEK Autosampler

PEEK Capillary 0.25*1.59 mm (1/16”) 3m

Finger Tight Fitting PEEK

Anionic Guard Column

Cationic Guard Column

Ferrule f.1/16″ Capillary Mat. PTFE TM used in IC Systems for Cond. Detector

Fitting 1/4-28 Gray with Knurled Screw Head 1/16”