Aromatic Hydrocarbon Analyser
Aromatic Hydrocarbon Analyser is a dedicated system based on high-performance liquid chromatography (HPLC) to determine aromatic hydrocarbon types including monoaromatic, di-aromatic, and polyaromatic hydrocarbon contents in kerosene, diesel fuels and petroleum distillates boiling in the range from 150 to 400 °C. Also, this instrument uses an accepted method for the determination of total aromatics and total saturates in additive-free lube base stocks.

FEATURES
- Support for highly accurate analysis of middle distillates and other matrices
- One method for determination of total aromatics and total saturates
- Innovative, reliable and easy-to-use
- Best balance of cost & efficiency
- Upgradable and durable design
- Full control by PC
- Powerful data analysis software
- Exceptional sensitivity with low detection limits
- Outstanding performance, peak resolution and analysis speed
SPECIFICATION
Pump |
Analytical stainless-steel low-pressure gradient version, programmable dual piston pump head for low pulsation, camshaft constantly lubricated, Flow rate: 0.001-10.000 ml/min, Pressure range: 0-40 MPa (0-6000 psi) |
Injection System | Automatic Sample Injector System, Sample Capacity: 120 samples (1.5 ml), Sample Loop: 100 µl, Carry Over: < 0.05% with wash program |
Backflush Valve | Manual or automatic flow-switching valve operating at pressures up to 40 MPa |
Column Oven Temperature | 30-100 ˚C |
Degasser | Integrated vacuum degasser |
Solvent Organizer | Inert plastic tray with 4 bottles |
Detector | Refractive Index detector, Refractive index range: 1-1.75, Flow Rate: 0.2-3.0 ml/min, Linearity Range: 1000 µRIU, Noise: 5×10-9, Temperature setting: up to 55 ˚C, Cell Volume: 9 µl |
Including |
|
INDUSTRIES
METHODS
ASTM D 6591 | Standard Test Method for Determination of Aromatic Hydrocarbon Types in Middle Distillates—High Performance Liquid Chromatography Method with Refractive Index Detection |
ASTM D 6379 | Standard Test Method for Determination of Aromatic Hydrocarbon Types in Aviation Fuels and Petroleum Distillates—High Performance Liquid Chromatography Method with Refractive Index Detection |
ASTM D 7419 | Standard Test Method for Determination of Total Aromatics and Total Saturates in Lube Basestocks by High Performance Liquid Chromatography (HPLC) with Refractive Index Detection |
SPARES & ACCESSORIES

HPLC Installation kit II

Cutter f. Stainless Steel Capillary and Plastic Tubing

Stainless Steel Capillary (1/16”) 1m × 2

Fitting 1/16” Stainless Steel × 10

Ferrule 1/16” Stainless Steel × 10

Porous Solvent Filter × 4

Exchangeable Filter Element (1 package=5 pcs.) × 1 “

Fingertight Fitting PEEK

“PEEK Connector 1/16″”-1/16″” incl. Fitting + Ferrule “

Fitting 1/8“PA6.6

Ferrule 1/8“TFM

Check Valve Cartridge

Ceramic Piston, Analytical

Secondary Sealing Ring Analytical

Primary Sealing Ring PE Analytical