Combustion Ion Chromatography Analyzer
Combustion Ion Chromatography (CIC) extends the range of chromatography to all types of combustible samples. The focus here is primarily on the simultaneous determination of the various halogens and sulfur in widely differing matrices. Combustion chromatography is ideal for routine analysis in a variety of fields, as neither details about the nature of the sample matrix need to be known nor complicated method development is necessary. Not only is combustion chromatography recommended for quality control of raw materials, intermediates and finished products, but the method is also suitable for straight forward and exact monitoring of compliance with the relevant laws, standards and regulatory requirements in the environmental field (e.g. DIN EN 228, IEC 605021, RoHS, WEEE, …).

FEATURES
- Extended range of application of chromatography for all kinds of combustible samples (solid, liquid and gaseous)
- Simultaneous determination of sulfur and halogens
- Quantification of the concentration for each halogen
- Ideal for checking the latest analytical standards with regard to halogen-free products (RoHS, WEEE …)
- High sample throughput, precision, and accuracy
- Clarity chromatography software for control and data management
- Flame sensor ensures optimum combustion time with a universal method
- Compliance with FDA and GLP standards
- Calibration with just one standard thanks to ISS Partial Loop Injection Technique
- Fully automated sample preparation for solid and liquid samples with just one modular sample changer.
SPECIFICATION
|
Conductivity Measuring Range |
up to 20000 μS/cm at 1 – 20 Hz sample frequency, Auto zero function for the entire measuring range, Noise: 0.1 nS/cm |
| Suppression | Electrolytic Suppressor |
| Column Oven Temperature | 30 °C -90 °C |
| Pump | Isocratic Pumps (analytical, non-metal – Peek version), Pressure Range: 0-40 MPa (0-6000 PSI), Flow rate: 0.001 – 10 ml/min |
| Degasser | Integrated 1-channel vacuum degasser |
| Determination of Total Fluorine, Chlorine and Sulfur in propane and propylene | |
| Total Halides | (Range: 1-100 ppm), Chloride, Fluorides: (Range: 1-500 ppm), (Range: 1-10 0ppm) |
| Parameters | Syringe liquid module/ Boat solids module |
| Sample introduction | Liquids/Solids |
| Working Range | 0.01 – 10.000 mg/kg/ 0.01 – 10.000 mg/kg |
| Sample Matrix | Light hydrocarbons/ Heavy hydrocarbons, solids |
| Quantity of Samples | 1 – 100 µL/ 0.1 – 100 mg |
| Analysis Time | 15 min/ 15 min |
| Relative Standard Deviation | < 2% (> 1 ppm)/ < 5% (> 1 ppm) |
| Furnace Temperature | 1250 °C Max |
| Including |
|
INDUSTRIES
METHODS
| ASTM D7359-14 | Standard Test Method for Total Fluorine, Chlorine and Sulfur in Aromatic Hydrocarbons and Their Mixtures by Oxidative Pyrohydrolytic Combustion followed by Ion Chromatography Detection (Combustion Ion Chromatography CIC) |
| UOP991-13 | Chloride, Fluoride, and Bromide in Liquid organics by Combustion Ion Chromatography (CIC) |
| ASTM D5987-96 | Standard Test Method for Total Fluorine in Coal and Coke by Pyrohydrolytic Extraction and Ion Selective Electrode or Ion Chromatograph Methods |
| ASTM D7994-17 | Standard Test Method for Total Fluorine, Chlorine, and Sulfur in Liquid Petroleum Gas (LPG) by Oxidative Pyrohydrolytic Combustion Followed by Ion Chromatography Detection (Combustion Ion Chromatography CIC) |
DOCUMENTS
SPARES & ACCESSORIES

Porous Solvent Filter

Injection Needle for Autosampler

Check Valve Cartridge/Ceramic

Secondary Sealing Ring Analytical

Primary Sealing Ring PE Analytical

Injection Port incl. Sealing PEEK Autosampler

PEEK Capillary 0.25*1.59 mm (1/16”) 3m

Finger Tight Fitting PEEK

Anionic Guard Column

Organic Acid Guard Column

Ferrule f.1/16″ Capillary Mat. PTFE TM used in IC Systems for Cond. Detector

Fitting 1/4-28 Gray with Knurled Screw Head 1/16”